8858cc永利官网(国际)俱乐部 - Limited Company

Mall
EN
CN VN RU

AQMS-500 Sulfur Dioxide Analyzer(SO2)

Product Summary:

FPI AQMS-500 sulfur dioxide (SO2) analyzer applies UV fluorescence technology with the photomultiplier tube (PMT) to measure SO2.

Quote Now
Product overview Product features
Product overview

FPI AQMS-500 sulfur dioxide (SO2) analyzer applies UV fluorescence technology with the photomultiplier tube (PMT) to measure SO2.

Principle
UV Fluorescence
Принцип
УФ Флуоресценция
Standard Range

Max:0~20ppm 

Min:0~100ppb

 (Selectable)

Стандартный диапазон

Max:0~20ppm 

Min:0~100ppb

 (выбор)

Zero Noise
≤0.25ppb (RMS)
Нулевой шум
≤0.25ppb (RMS)
Span Noise
≤2.5ppb (RMS)
Пролетный шум
≤2.5ppb (RMS)
Display
Digital
Отображение
Цифровое
Lower Detectable Limit
0.5ppb
Минимальный предел обнаружения
0.5ppb
Zero Drift
<1ppb/24h
Дрейф нуля
<1ppb/24ч
Span Drift

±5ppb/24h

Дрейф пролета

±5ppb/24ч

Linearity
<1%F.S.
Линейность
<1%F.S.
Precision
<1%
Точность
<1%
Response Time
T90<120s
Время реакции
T90<120сек
Sample Flow Rate
(650±65)sccm
Расход пробы
(650±65)sccm
Data Transmission

2 channel analog (4~20) mA;  

12 digital input/output; 

4-way relay output;                             

Передача информации

2 канал аналог (4~20) мA;

12 цифровой вход/выход; 

4-х контактный релейный выход;

Calibration
Multi-point calibrator
Калибровка
Многоточечный калибратор
Communication
RS232/RS485/Ethernet
Коммуникационный интерфейс
RS232/RS485/Ethernet
Operating Temperature
US EPA Specification 20~30°C, Actual applicable:0~40°C
Рабочая температура
US EPA Спецификация 20~30°C,Фактически применимая:0~40°C
Operating Humidity
0~95%RH(No:condensation)
Рабочая влажность
0~95%RH(Без конденсации)
Power Requirement

220V AC/50Hz;

110V AC/60Hz

Требуемая мощность

220V AC/50Hz;

110V AC/60Hz

Dimensions and Weight
178(H)x432(W)x609(D)mm, 22kg
Габаритные размеры и вес
178(Высота)x432(Ширина)x609(Глубина)мм, 22кг


Product features


  • Compliance with US EPA reference method;
  • Various outputs include ethernet and RS232;
  • User friendly interface with large screen;
  • Continuous system diagnosis with alarm;
  • Multi-tasking software allows viewing test variables while operating;
  • Temperature and pressure compensation;
  • Internal data logging with 1 min to 365 day multiple  averages;
  • Critical orifices provide flow stability;


Quote Now
  • Name*
  • Email*
  • PhoneNumber*
  • Country/State*
  • Message*
Captcha*
Can’t read? Try another
I agree that my data from this contact form will be collected and processed to answer my request
Copyright 2023 FPI Group All Rights Reserved.浙ICP备11039119号 Powered ByHANSUN
Request for Quotation
Do you have any questions or requests?
Fill this form to contact our experts.
Name *
Email *
Message
Submit
XML 地图
XML 地图