8858cc永利官网(国际)俱乐部 - Limited Company

Mall
EN
CN VN RU
AQMS-300 Ozone Analyzer(O₃)
Product Summary:
FPI AQMS-300 Ozone analyzer measures ambient O3 concentration in ppb level by utilizing UV photometric absorption technology.
Quote Now
Product overview Product features Media materials
Product overview

FPI AQMS-300 Ozone analyzer measures ambient O3 concentration in ppb level by utilizing UV photometric absorption technology.


Principle

UV Photometric

Принцип
УВ Фотометрия

Standard Range

Max:0~10ppm Min:0~100ppb (Selectable)


Стандартный диапазон

Max:0~10ppm Min:0~100ppb

 (выбор)

Zero Noise

0.4ppb (RMS)

Нулевой шум
0.4ppb (RMS)

Span Noise

<2.5ppb (RMS)

Пролетный шум
<2.5ppb (RMS)

Lower Detectable Limit 

0.8ppb (RMS)

Минимальный 

предел обнаружения

0.8ppb (RMS)

Zero Drift

±2ppb/24h

Дрейф нуля
±2ppb/24ч

Span Drift

±5ppb/24h

Дрейф пролета

±5ppb/24ч

Linearity

<1%F.S.

Линейность
<1%F.S.

Precision

<1%

Точность
<1%

Response Time 

T90<30s

Время реакции
T90<30сек

Output    

RS232/RS485/Ethernet

Вывод
RS232/RS485/Ethernet

Calibration 

Multi-point Calibrator

Калибровка
Многоточечный калибратор
Power Requirement

220V AC/50Hz;

110V AC/60Hz


Требование к питанию

220V AC/50Hz;

110V AC/60Hz



Product features
  • Accurate direct UV absorption with reference comparison; 
  • Compliance with US EPA equivalent method; 
  • Various outputs include ethernet and RS232; 
  • User friendly interface with large screen; 
  • Continuous system diagnosis with alarm; 
  • Multi-tasking software allows viewing test variables while operating; 
  • Temperature and pressure compensation; 


 Principle
The concentration of ambient ozone is proportional to UV light absorption since there is a significant characteristic absorption for ozone on wavelength of 254nm.
Periodical diversion on sample flow passing through the ozone scrubber will generate reference measurement, which is compared with sample measurement to provide stable and representative result.

Ozone scrubber
The ozone scrubber is filled with MnO2 as catalyst, which will convert O3 to O2 to form reference gas. Meanwhile, the presence of other components remains the same.

Data storage and analysis
Stored data are easily retrievable through the serial or ethernet port via PC client software, allowing operators to perform predictive diagnostics and enhanced data analysis by tracking parameter trends.


Media materials
Related Content
Quote Now
  • Name*
  • Email*
  • PhoneNumber*
  • Country/State*
  • Message*
Captcha*
Can’t read? Try another
I agree that my data from this contact form will be collected and processed to answer my request
Copyright 2023 FPI Group All Rights Reserved.浙ICP备11039119号 Powered ByHANSUN
Request for Quotation
Do you have any questions or requests?
Fill this form to contact our experts.
Name *
Email *
Message
Submit
XML 地图
XML 地图